[1]陈武,黄毅,力刚,等.时差法超声波测流系统在刘老涧泵站的应用分析[J].江苏水利,2022,(增刊2):61-64.
 CHEN Wu,HUANG Yi,LI Gang,et al.Application analysis of ultrasonic flow measurement system with time difference method in Liulaojian Pumping Station[J].JIANGSU WATER RESOURCES,2022,(增刊2):61-64.
点击复制

时差法超声波测流系统在刘老涧泵站的应用分析()
分享到:

《江苏水利》[ISSN:1006-6977/CN:61-1281/TN]

卷:
期数:
2022年增刊2
页码:
61-64
栏目:
水文水资源
出版日期:
2022-12-30

文章信息/Info

Title:
Application analysis of ultrasonic flow measurement system with time difference method in Liulaojian Pumping Station
文章编号:
1007-7839(2022)Sup2-0061-04
作者:
陈武黄毅力刚施翔
(江苏省骆运水利工程管理处,江苏 宿迁 223800)
Author(s):
CHEN Wu HUANG Yi LI Gang SHI Xiang
(Luoyun Water Engineering Management Division of Jiangsu Province, Suqian 223800, China)
关键词:
时差法测量原理应用分析远程诊断
Keywords:
time difference method measurement principle statistical analysis remote diagnostic system
分类号:
TV675
文献标志码:
A
摘要:
刘老涧泵站上游引河安装时差法超声波流量实时监测系统,以该流量监测系统为例,介绍时差法超声波流量计在大型泵站引河渠道中应用的工作原理、安装方式、流量计算方法等。从走航式ADCP与时差法超声波测流系统同步流量测验的比测结果看,结合泵站机组运行统计分析,该流量实时监测系统测得流量精度满足相关规范要求。在大型泵站流量测量中,该监测系统具备自动化和信息化优势,可较为明显地提高泵站各项监测能力,所获得的结果准确度更高,具备较高的应用与推广价值。
Abstract:
The upstream approach of Liulaojian pumping station is installed with ultrasonic flow real-time monitoring system. Taking this flow monitoring system as an example, the working principle, installation mode, flow calculation method, etc. of the application of ultrasonic flowmeter with time difference method in the approach channel of large pumping station are introduced. From the comparison results of synchronous flow measurement of traveling ADCP and time difference ultrasonic flow measurement system, combined with the statistical analysis of pumping station unit operation, the flow accuracy measured by the flow real-time monitoring system meets the requirements of relevant specifications. In the flow measurement of large pumping stations, the monitoring system has the advantages of automation and information technology, which can significantly improve the monitoring capabilities of the pumping stations. The results obtained are more accurate and have higher application and promotion value.

参考文献/References:

[1]潘忠良,顾晓蕾,王维汉,等. 超声波流量计在泵站单位电量提水量率定中的应用实践[J]. 浙江水利科技, 2015,43(5):80-82,96.
[2]杜晓泽,刘胜祥. 时差法超声波流量计流量系数影响因素分析[J]. 工业计量,2019,29(2):14-15,38.
[3]孙振华. 超声波流量计在大型泵站流量测试中的应用[J]. 中国农村水利水电,2010(3):130-131,135.
[4]周济人,杨华,成立,等. 超声波流量计测试大型低扬 程泵站流量的模型试验[J]. 排灌机械,2009,27(1):51-54.
[5]邹蓬,吕传玉,李凤名. 时差法超声波流量计的原理和设计[J]. 建设科技,2012(4):88-89.
[6]吉庆伟,李进东,张一祁,等. 时差式超声波流量计在刘老涧泵站中的应用及分析[J]. 浙江水利科技,2021(6):68-71.
[7]陈兴农,李仪,胡天忠,等. 时差法超声波流量计在大型渠道的应用分析[J]. 水利信息化,2021(3):32-36.
[8]水利部水文局,水利部水利信息中心. 河流流量测验规范:GB 50179—2015[S]. 北京:中国计划出版社,2015.

备注/Memo

备注/Memo:
收稿日期:2022-11-01
作者简介:陈武(1987—),男,工程师,本科,主要从事泵站运行管理工作。E-mail:450242588@qq.com