[1]刘建龙,李志爽,陈书宁,等.秦淮新河泵站前池流态改善措施研究[J].江苏水利,2024,(12):24-29.
 LIU Jianlong,LI Zhishuang,CHEN Shuning,et al.Research on improvement measures of flow pattern in fore bay of Qinhuaixinhe Pumping Station[J].JIANGSU WATER RESOURCES,2024,(12):24-29.
点击复制

秦淮新河泵站前池流态改善措施研究()
分享到:

《江苏水利》[ISSN:1006-6977/CN:61-1281/TN]

卷:
期数:
2024年12期
页码:
24-29
栏目:
水利规划与设计
出版日期:
2024-12-15

文章信息/Info

Title:
Research on improvement measures of flow pattern in fore bay of Qinhuaixinhe Pumping Station
文章编号:
1007-7839(2024)12-0024-0006
作者:
刘建龙1李志爽2陈书宁1薛铮1王翘楚1成立2
(1. 江苏省秦淮河水利工程管理处,江苏 南京 210000;2. 扬州大学 水利科学与工程学院,江苏 扬州 225100)
Author(s):
LIU Jianlong1 LI Zhishuang2 CHEN Shuning1 XUE Zheng1 WANG Qiaochu1 CHENG Li2*
(1. Management Division of Qinhuai River Hydraulic Engineering of Jiangsu Province, Nanjing 210000, China;2. College of Hydraulic Science and Engineering, Yangzhou University, Yangzhou 225100, China)
关键词:
泵站前池流态整流措施数值模拟
Keywords:
pumping station fore bay flow pattern rectification measures numerical simulation
分类号:
TV675
文献标志码:
A
摘要:
采用CFD数值模拟方法,以秦淮新河泵站为研究对象,开展泵站前池流态分析及改善措施的数值模拟研究。结果表明在超低水位工况下,前池导流墩附近存在大面积的回流区影响边机组的进水条件,导致导流墙边机组的流速均匀度和加权平均角远低于其他机组。增设圆形通水孔和“Y”形导流墩均可改善前池内的流态,消除导流墙附近的不良流态,提高边机组的流速均匀度及加权平均角,研究成果可为同类泵站优化改造提供参考。
Abstract:
Using the CFD numerical simulation method and taking the Qinhuaixinhe Pump Station as the research object, a numerical simulation study on the flow pattern analysis and improvement measures of the forebay of the pump station is carried out. The results show that under the condition of ultra-low water level, there is a large area of recirculation zone near the diversion pier of the fore bay, which seriously affects the water inlet condition of the side unit, resulting in the flow velocity uniformity and weighted average angle of the side unit being much lower than that of the other units. The addition of circular water holes and Y-shaped diversion pier can improve the flow pattern in the fore bay, eliminate the bad flow pattern near the diversion wall, and improve the flow velocity uniformity and weighted average angle of the side unit. The research results can provide a reference for the design and transformation of pumping stations.

参考文献/References:

[1]黄竞争,张先毅,吴峥,等. 长江感潮河段潮波传播变化特征及影响因素分析[J]. 海洋学报,2020,42(3):25-35.
[2]童建伟. 秦淮新河泵站偏离设计工况运行分析与对策[J]. 江苏水利,2023(3):57-60.
[3]朱明成,苏福,滕娟,等. 感潮河段支流口门枢纽局部流态优化试验研究[J]. 水运工程,2021(6):110-114.
[4]张聪聪,周春峰,周艳霞,等. “Y”形导流墩几何参数对侧向进水泵站前池流态影响[J]. 南水北调与水利科技,2020,18(3):192-200.
[5]张从从,韦爱群,李金宝,等. 基于模型试验的导流墩对闸站合建工程通航水流条件的影响研究[J]. 江苏水利,2019(4):13-17.

相似文献/References:

[1]张少卿,杨 波,张 瑾.常熟水利枢纽清污机的选型设计与研究[J].江苏水利,2016,(03):6.
 ZHANG Shaoqing,YANG Bo,ZHANG Jin.Type selection design and research on cleaning machine of Changshu hydro project[J].JIANGSU WATER RESOURCES,2016,(12):6.
[2]钱睿智,丁昌言,王亚宾,等.单位扬程有功功率法泵站流量关系定线[J].江苏水利,2016,(03):26.
 QIAN Ruizhi,DING Changyan,WANG Yabin,et al.Unit lift active power method for discharge relationship alignment of pump station[J].JIANGSU WATER RESOURCES,2016,(12):26.
[3]沈志新,朱丽向.灌河北泵站达标创建工作的探索[J].江苏水利,2016,(03):46.
 SHEN Zhixin,ZHU Lixiang.Exploration of standardized unit establishment of Guanhe Northern pump station[J].JIANGSU WATER RESOURCES,2016,(12):46.
[4]黄璐,朱文彪,王鼎,等.运东闸站多年降水量特性分析[J].江苏水利,2016,(10):46.
 HUANG Lu,ZHU Wenbiao,WANG Ding,et al.Analysis of precipitation characteristics of Yundong sluice station[J].JIANGSU WATER RESOURCES,2016,(12):46.
[5]薛士平,杨晓红,吴佩锋.泵站弯道引水渠水流流动特性影响分析[J].江苏水利,2017,(01):9.
 XUE Shiping,YANG Xiaohong,WU Peifeng.Analysis of the flow characteristics influence in the bend channel of pump station[J].JIANGSU WATER RESOURCES,2017,(12):9.
[6]王骏秋,万 泉,王 江.基于合并效率法对江都第三抽水站正反出流分析[J].江苏水利,2017,(01):27.
 WANG JunQiu,WAN Quan,WANG Jiang.Analysis of positive and negative flow out Jiangdu No.3 pumping station based on combined efficiency method[J].JIANGSU WATER RESOURCES,2017,(12):27.
[7]顾春雨,薛士平,杨晓红.泵站锥形侧向进水前池水流流动特性分析[J].江苏水利,2017,(02):17.
 GU Chunyu,XUE Shiping,YANG Xiaohong.Analysis of the flow characteristics in the conical forebay wit h side-intake of the pump station[J].JIANGSU WATER RESOURCES,2017,(12):17.
[8]吴晓兰,马晓辉,许一新.泵站正向进水前池水流流动均匀性分析[J].江苏水利,2017,(03):53.
 WU Xiaolan,MA Xiaohui,XU Yixin.Analysis of flow uniformity of front inflow forebay in the pump station[J].JIANGSU WATER RESOURCES,2017,(12):53.
[9]杨卫星,汤仲仁.南通市九圩港提水泵站工程裂缝处理施工工艺[J].江苏水利,2017,(04):18.
 YANG Weixing,TANG Zhongren.The construction process of concrete crack treatment in Jiuweigang pump station[J].JIANGSU WATER RESOURCES,2017,(12):18.
[10]吴 钢,孟慧玲,王嘉豪.江尖水利枢纽泵站静音改造的实践与思考[J].江苏水利,2017,(04):58.
 WU Gang,MENG Huiling,WANG Jiahao.Practice and Reflection on the reform of Jiangjian pump station[J].JIANGSU WATER RESOURCES,2017,(12):58.

备注/Memo

备注/Memo:
收稿日期:2024-09-19
基金项目:江苏省水利科技项目(2022017)
作者简介:刘建龙(1982—),男,正高级工程师,主要从事水利工程建设与运行管理工作。E-mail:20846457@qq.com
通信作者:成立(1975—),男,教授,博士,研究方向为泵站工程。E-mail:chengli@yzu.edu.cn
更新日期/Last Update: 2024-12-15