[1]宋 峰.水工混凝土表面不同防护材料抗渗性能对比试验研究[J].江苏水利,2020,(03):43-46+50.
 SONG Feng.Comparative experimental study on the impermeability of different protective materials on the hydraulic surface of concrete[J].JIANGSU WATER RESOURCES,2020,(03):43-46+50.
点击复制

水工混凝土表面不同防护材料抗渗性能对比试验研究()
分享到:

《江苏水利》[ISSN:1006-6977/CN:61-1281/TN]

卷:
期数:
2020年03期
页码:
43-46+50
栏目:
水利工程建设
出版日期:
2020-04-27

文章信息/Info

Title:
Comparative experimental study on the impermeability of different protective materials on the hydraulic surface of concrete
文章编号:
1007-7839(2020)03-0043-04
作者:
宋 峰
江苏省淮沭新河管理处, 江苏 淮安 223005
Author(s):
SONG Feng
The New Huaishu River Management Division of Jiangsu Province, Huaian 223005, Jiangsu
关键词:
水工混凝土 室内试验 表面防护材料 抗渗性能
Keywords:
hydraulic concrete laboratory test surface protective materials impermeability
分类号:
TV441
文献标志码:
B
摘要:
为提高水工钢筋混凝土结构抗渗性能。根据水工混凝土服役环境的特殊性,设计开展室内混凝土防护材料性能检测试验方法,对比分析水工建设中应用较为广泛的HS943环氧厚浆、施而固、优止水以及永凝液4种防护材料的混凝土抗渗性能。试验表明:(1)HS943环氧厚浆与施而固防护材料涂层防渗效果明显。环氧厚浆材料内部微观结构密实无孔隙,能够阻止水分的渗入,而施而固材料内部微观结构及涂层阻水性则相反;(2)优止水材料成分与施而固相似,但涂层防渗效果较施而固差;(3)永凝液能填充结构内部孔隙但不能阻止水从结构表面进行浸入,涂层抗渗效果一般。
Abstract:
In order to improve the impermeability of hydraulic reinforced concrete structures, according to the particularity of the service environment of hydraulic concrete, an experimental test method for the performance of indoor concrete protective materials was designed. The impermeability of concrete with HS943 high build epoxy, solidification, excellent water-stop and permanent condensate, which were widely used in hydraulic construction, was compared and analyzed. The test results showed that:(1)The anti-seepage effect of two protective materials coating as HS943 high build epoxy and solidification was obvious. The internal microstructure of high build epoxy material was compact and porous, which could prevent water infiltration, while the internal microstructure and the water resistance of the coating of solidification material were opposite.(2)The composition of the excellent water-stop material was similar to that of solidification, but the coating anti-seepage effect of the excellent water-stop was worse than that of the solidification.(3)Permanent condensate could fill the internal pore of the structure, but could not prevent water from immersing from the structure surface, so that the coating anti-seepage effect was general.

参考文献/References:

[1] 吴明. 对两类渗透性防水材料的思考[J]. 中国建筑防水, 2013(16):7-11.
[2] 程永锋, 张琰, 刘华清, 等. 基于外涂防腐材料的混凝土抗压强度和抗渗性能研究[J]. 混凝土, 2016(6):20-23.
[3] 王子迪. 孔填充材料对混凝土抗渗性能影响研究[J]. 混凝土, 2013(4):37-39.
[4] 廖文兵, 刘清, 塞尔江·哈力克. 渗透结晶材料对乌鲁木齐地区混凝土抗渗性能的试验研究[J]. 混凝土, 2015(1):155-157.
[5] 牛荻涛. 混凝土结构耐久性与寿命预测[M]. 北京:科学出版社, 2003:13-15.
[6] 李新宇, 方坤河, 等. 软水溶蚀作用下水工碾压混凝土渗透特性研究[J]. 长江科学院院报, 2008, 25(4):81-84.
[7] 郭远臣, 谢波, 王鸿东, 等. 渗透结晶型高抗渗生态水工混凝土性能研究[J]. 混凝土, 2013(6):120-123.
[8] GB/T 50082-2009普通混凝土长期性能和耐久性能试验方法标准[S].
[9] BASHEER P A M, BASHEER L, CLELAND D J, et al. Surface treatments for concrete: assessmentmethods and reported performance[J]. Construction & Building Materials, 1997, 11(7/8):413-429.
[10] DL/T 5150-2017水工混凝土试验规程[S].
[11] SL/352-2006水工混凝土试验规程[S].

备注/Memo

备注/Memo:
收稿日期:2019-09-21
作者简介:宋峰(1989-),男,工程师,主要从事水利工程安全运行的维护与管理工作。
更新日期/Last Update: 2020-03-20