[1]祁洁,刘军,王彦军,等.宝应站清污机的优化设计和应用实践[J].江苏水利,2024,(03):49-53.
 QI Jie,LIU Jun,WANG Yanjun,et al.Optimization design and application practice of the sewage cleaning machine at Baoying Station[J].JIANGSU WATER RESOURCES,2024,(03):49-53.
点击复制

宝应站清污机的优化设计和应用实践()
分享到:

《江苏水利》[ISSN:1006-6977/CN:61-1281/TN]

卷:
期数:
2024年03期
页码:
49-53
栏目:
水利工程管理及防汛防旱
出版日期:
2024-03-15

文章信息/Info

Title:
Optimization design and application practice of the sewage cleaning machine at Baoying Station
文章编号:
1007-7839(2024)03-0049-0005
作者:
祁洁1刘军1王彦军2刘菁1杨红辉1张少卿2
(1. 南水北调东线江苏水源有限责任公司,江苏 南京 210000;2. 曲阜恒威水工机械有限公司,山东 济宁 272000)
Author(s):
QI Jie1 LIU Jun1 WANG Yanjun2 LIU Jing1 YANG Honghui1 ZHANG Shaoqing2
(1. The Eastern Route of South-to-North Water Diversion Jiangsu Water Resource Co., Ltd., Nanjing 210000, China;2. Qufu Hengwei Hydraulic Machinery Co., Ltd., Jining 272000, China)
关键词:
宝应站清污机原因分析优化设计
Keywords:
Baoying Station sewage cleaning machine cause analysis optimization design
分类号:
TV675
文献标志码:
B
摘要:
宝应站作为南水北调东线一期工程第一级抽水站,自2005年建成以来发挥了抽水、排涝等功能。泵站地处里下河地区,水草量巨大,清污机长期高负荷运行导致故障。总结分析历年的改造维修和运行管理经验,结合现场实际情况,研究宝应站清污机整体强度、牵引力、功率、链条、齿耙结构、轨道、格栅、材质等方面优化设计方案。根据设计完成制造安装,通过在南水北调宝应站调水运行过程中实际应用,清污效果及运行稳定性均达到预期效果。
Abstract:
As the first stage pumping station of the first phase of the eastern route of south to north water diversion project, Baoying Station has played the functions of pumping and drainage since its completion in 2005. The pumping station is located in the Lixia River area, the amount of water grass is huge, and the long-term high load operation of the sewage cleaning machine has caused malfunctions. Summarize and analyze the experience of renovation, maintenance, and operation management over the years, combined with actual situation on site, research the optimization design plan for the overall strength, traction, power, chain, tooth rake structure, track, grid, material and other aspects of Baoying Station cleaning machine According to the design, the manufacturing and installation have been completed. Through practical application in the water transfer operation of Baoying Station in the south to north water diversion project, the cleaning effect and operation stability have achieved the expected results.

参考文献/References:

[1]中华人民共和国住房和城乡建设部. 泵站设计规范:GB 50265—2010[S]. 北京:中国计划出版社,2010.
[2]谢晓勇. 大坝安全监测设计与施工技术的分析研究[J]. 珠江水运,2020(7):40-42.
[3]虞晓峰. 排涝泵站回转式清污机清污能力不足的改造[J]. 浙江水利科技,2010(4):108-110.
[4]高亮,龙俊,马士磊,等. 石港泵站回转式清污机优化及其应用[J]. 江苏水利,2017(7):4-8.

相似文献/References:

[1]张少卿,杨 波,张 瑾.常熟水利枢纽清污机的选型设计与研究[J].江苏水利,2016,(03):6.
 ZHANG Shaoqing,YANG Bo,ZHANG Jin.Type selection design and research on cleaning machine of Changshu hydro project[J].JIANGSU WATER RESOURCES,2016,(03):6.
[2]高 亮,龙 俊,马士磊,等.石港泵站回转式清污机优化及其应用[J].江苏水利,2017,(07):36.
 GAO Liang,LONG Jun,MA Shilei,et al.Optimization and application of rotary cleaning machine in Shigang Pump Station[J].JIANGSU WATER RESOURCES,2017,(03):36.

备注/Memo

备注/Memo:
收稿日期:2023-08-19
作者简介:祁洁(1979—),女,高级工程师,硕士,主要从事水利工程管理工作。E-mail: 83783111@qq.com
更新日期/Last Update: 2024-03-15