[1]查 红,黄宏家,余乃旺,等.射阳河闸(闸上游)水文站流量间测可行性分析[J].江苏水利,2020,(07):42-47.
 ZHA Hong,HUANG Hongjia,YU Naiwang,et al.Feasibility analysis on the intermittent measurement of hydrological station in the Sheyang River Sluice(upstream of the sluice)[J].JIANGSU WATER RESOURCES,2020,(07):42-47.
点击复制

射阳河闸(闸上游)水文站流量间测可行性分析()
分享到:

《江苏水利》[ISSN:1006-6977/CN:61-1281/TN]

卷:
期数:
2020年07期
页码:
42-47
栏目:
水文水资源
出版日期:
2020-07-25

文章信息/Info

Title:
Feasibility analysis on the intermittent measurement of hydrological station in the Sheyang River Sluice(upstream of the sluice)
文章编号:
1007-7839(2020)07-0042-06
作者:
查 红 黄宏家 余乃旺 孙成林 陈 刚
江苏省水文水资源勘测局盐城分局, 江苏 盐城 224051
Author(s):
ZHA Hong HUANG Hongjia YU Naiwang SUN Chenglin CHEN Gang
Yancheng Hydrology and Water Resources Investigation Bureau of Jiangsu Province, Jiangsu 224051, Yancheng, China
关键词:
水文站 一潮推流法 综合关系 巡测规范 间测
Keywords:
hydrological station one-tide flow method comprehensive relationship inspection specifications inter-measurement
分类号:
TV123
文献标志码:
B
摘要:
选用2003—2017年连续15年射阳河闸(闸上游)站实测流量、定线、推流等成果资料,对该站一潮推流法综合关系进行分析,依据巡测规范,从采用资料、相关因素控制率、关系线间偏离误差、三种检验、精度等5个方面分析该站实行流量间测的可行性,并结合该站工情、水情实际提出间测方案,可为闸坝类水文站间测分析提供参考。
Abstract:
The actual data of measured flow, alignment and flow estimation of Sheyang River Sluice(upstream of the sluice)station for 15 consecutive years from 2003 to 2017 were selected to analyze the comprehensive relationship of the one-tide flow method at the station. According to the survey specification, According to the patrol survey specifications, the feasibility of implementing inter-measurement at the station was analyzed from five aspects: the use of data, the control rate of relevant factors, the deviation error between the relationship lines, the three kinds of inspections, and accuracy. And combined with the actual work conditions and water conditions of the station, the inter-measurement scheme was proposed, which could provide a reference for the inter-measurement analysis of dam and sluice type hydrological stations.

参考文献/References:

[1] 水利部水文局. SL195—2015 水文巡测规范[S]. 北京:中国水利水电出版社, 2016.
[2] 杨崇勇, 操丕军. 康定(四)站流量间测分析[J]. 四川水利, 2019(3):86-88.
[3] 冯省波. 水文站流量停间测可行性浅析[J]. 海河水利, 2016(4):43-44.
[4] 郭建平, 唐晓春. 张家港闸水文站实施流量间测方案探讨[J]. 治淮, 2013(12):80.
[5] 王玲. 巢湖闸2004—2013年堰闸流量综合关系线分析[J]. 江淮水利科技, 2015(4):36-45.

相似文献/References:

[1]夏明嫣.长江下游潮汐河口段水位流量关系分析[J].江苏水利,2018,(05):27.
 XIA Mingyan.Analysis on the stage-discharge relation in the tidal estuary of the lower reaches of the Yangtze River[J].JIANGSU WATER RESOURCES,2018,(07):27.
[2]房照娟,曹小伟,张彩云,等.马甸港闸水文站水位流量关系分析[J].江苏水利,2020,(01):50.
 FANG Zhaojuan,CAO Xiaowei,ZHANG Caiyun,et al.Analysis on the relationship between water level and discharge of the hydrological station of Madian Port Sluice[J].JIANGSU WATER RESOURCES,2020,(07):50.
[3]臧力永,孙金凤,尹若燕.沭阳县岔流新开河桐槐树水文站防汛特征水位复核研究[J].江苏水利,2022,(12):27.
 ZANG Liyong,SUN Jinfeng,YIN Ruoyan.Study on recheck of flood control characteristic water level at Tonghuaishu Hydrometric Station of Chaliuxinkai River in Shuyang County[J].JIANGSU WATER RESOURCES,2022,(07):27.

备注/Memo

备注/Memo:
收稿日期:2020-02-23
作者简介:查红(1968—),男,高级工程师,硕士,主要从事水文工作。E-mail: 747008620@qq.com
更新日期/Last Update: 2020-07-20