[1]祁德丽,吕鸿燕,陈 武.泵站水冷系统漏液报警器设计[J].江苏水利,2019,(01):60-62+66.
 QI Deli,LV Hongyan,CHEN Wu.Design of leakage alarm for water cooling system of pumping station[J].JIANGSU WATER RESOURCES,2019,(01):60-62+66.
点击复制

泵站水冷系统漏液报警器设计()
分享到:

《江苏水利》[ISSN:1006-6977/CN:61-1281/TN]

卷:
期数:
2019年01期
页码:
60-62+66
栏目:
水利工程管理
出版日期:
2019-01-15

文章信息/Info

Title:
Design of leakage alarm for water cooling system of pumping station
文章编号:
1007-7839(2018)12-0060-03
作者:
祁德丽吕鸿燕陈 武
江苏省骆运工程管理处,江苏 宿迁 223800
Author(s):
QI Deli LV Hongyan CHEN Wu
Luoyun Hydraulic Project Management Division of Jiangsu Province,Suqian 223800,Jiangsu
关键词:
泵站水冷系统漏液报警
Keywords:
pumping stationwater cooling systemleakage alarm
分类号:
TV675
文献标志码:
B
摘要:
江苏省骆运水利工程管理处的泵站控制中使用了同步电机循环水冷系统,为保证水冷系统的正常使用,防止漏液导致相关设备损坏而设计了专门用于漏液检测报警的方案。该方案以STM32F103处理器为核心,检测传感器的状态,在现场显示其告警信息,同时通过RS-485 Modbus方式将告警信息传输到远程监控系统上。实践证明,该新型漏液告警系统,可以达到实际使用要求,具有广阔的推广应用前景。
Abstract:
The circulating water cooling system of synchronous motor was used in the pumping station control of Luoyun Hydraulic Project Management Division of Jiangsu Province.In order to ensure the normal use of the water cooling system and prevent the leakage of the related equipment, a scheme for leak detection and alarm was designed specially.The scheme took STM32F103 processor as the core, detected the state of sensor, displayed alarm information on the spot, and transmitted alarm information to remote monitoring system by RS-485 Modbus.Practice had proved that the new type of liquid leakage alarm system could meet the practical use requirements and had broad application prospects.

参考文献/References:

[1]SL-61 2003 水文自动测报系统技术规范[S].北京:中华人民共和国水利部,2003.
[2]张仑.32位嵌入式系统硬件设计与调试[M].北京:机械工业出版社,2000.
[3]问泽杭,等.冷水机组在泵站冷却系统中的应用[J].机械排灌,2005,23(1):19-21.
[4]DB32/T 1360-2009 泵站运行规程[S].南京:江苏省质量技术监督局,2009.

相似文献/References:

[1]张少卿,杨 波,张 瑾.常熟水利枢纽清污机的选型设计与研究[J].江苏水利,2016,(03):6.
 ZHANG Shaoqing,YANG Bo,ZHANG Jin.Type selection design and research on cleaning machine of Changshu hydro project[J].JIANGSU WATER RESOURCES,2016,(01):6.
[2]钱睿智,丁昌言,王亚宾,等.单位扬程有功功率法泵站流量关系定线[J].江苏水利,2016,(03):26.
 QIAN Ruizhi,DING Changyan,WANG Yabin,et al.Unit lift active power method for discharge relationship alignment of pump station[J].JIANGSU WATER RESOURCES,2016,(01):26.
[3]沈志新,朱丽向.灌河北泵站达标创建工作的探索[J].江苏水利,2016,(03):46.
 SHEN Zhixin,ZHU Lixiang.Exploration of standardized unit establishment of Guanhe Northern pump station[J].JIANGSU WATER RESOURCES,2016,(01):46.
[4]黄璐,朱文彪,王鼎,等.运东闸站多年降水量特性分析[J].江苏水利,2016,(10):46.
 HUANG Lu,ZHU Wenbiao,WANG Ding,et al.Analysis of precipitation characteristics of Yundong sluice station[J].JIANGSU WATER RESOURCES,2016,(01):46.
[5]薛士平,杨晓红,吴佩锋.泵站弯道引水渠水流流动特性影响分析[J].江苏水利,2017,(01):9.
 XUE Shiping,YANG Xiaohong,WU Peifeng.Analysis of the flow characteristics influence in the bend channel of pump station[J].JIANGSU WATER RESOURCES,2017,(01):9.
[6]王骏秋,万 泉,王 江.基于合并效率法对江都第三抽水站正反出流分析[J].江苏水利,2017,(01):27.
 WANG JunQiu,WAN Quan,WANG Jiang.Analysis of positive and negative flow out Jiangdu No.3 pumping station based on combined efficiency method[J].JIANGSU WATER RESOURCES,2017,(01):27.
[7]顾春雨,薛士平,杨晓红.泵站锥形侧向进水前池水流流动特性分析[J].江苏水利,2017,(02):17.
 GU Chunyu,XUE Shiping,YANG Xiaohong.Analysis of the flow characteristics in the conical forebay wit h side-intake of the pump station[J].JIANGSU WATER RESOURCES,2017,(01):17.
[8]吴晓兰,马晓辉,许一新.泵站正向进水前池水流流动均匀性分析[J].江苏水利,2017,(03):53.
 WU Xiaolan,MA Xiaohui,XU Yixin.Analysis of flow uniformity of front inflow forebay in the pump station[J].JIANGSU WATER RESOURCES,2017,(01):53.
[9]杨卫星,汤仲仁.南通市九圩港提水泵站工程裂缝处理施工工艺[J].江苏水利,2017,(04):18.
 YANG Weixing,TANG Zhongren.The construction process of concrete crack treatment in Jiuweigang pump station[J].JIANGSU WATER RESOURCES,2017,(01):18.
[10]吴 钢,孟慧玲,王嘉豪.江尖水利枢纽泵站静音改造的实践与思考[J].江苏水利,2017,(04):58.
 WU Gang,MENG Huiling,WANG Jiahao.Practice and Reflection on the reform of Jiangjian pump station[J].JIANGSU WATER RESOURCES,2017,(01):58.

备注/Memo

备注/Memo:
收稿日期:2018-05-24 作者简介:祁德丽(1983—)女,本科,工程师,主要从事泵站管理、水文勘测等工作。
更新日期/Last Update: 2019-01-15